Sunday, September 29, 2019

National Electric Code 2020 Updates

National Electric Code 2020 Updates



The National Electric Code (NEC) is revised every 3 years. All 50 states utilize the code for their standards. I am going to outline the updates from the previous version. One of the changes I was glad to see is that service panels with 6 main disconnects are no longer permitted. I have long advised my clients to upgrade split panel service panels. Trying to explain how to disconnect the service and the fact that some breakers, many times 240 volt circuits actually cannot be disconnected. This makes the panel dangerous to work on. The homeowner’s are often confused on which breaker is actually the “main” when several breakers are either marked or look like a main service disconnect. Load calculations will also be reduced to account for higher efficiency appliances and lighting options. There has been a huge reduction in this area and many times a smaller service size (depending on the house) will be adequate. When I started performing home inspections the 240 volt appliances were 50-60 amps. Now those same appliances are 20-40 amps. Here are the other updates that a home inspector needs to know: 

  • Outdoor Emergency Service Disconnects are now required for one and two family dwellings. This is to ensure first responders, especially fire fighters can disconnect the electric supply to the house
  • Ground Fault Circuit Interrupters (GFCI) are now required on most 120 – 240 volt branch circuits. This includes clothes dryers, ranges, ovens, etc.
  • Serge protection devices are required for all dwelling units. Many home inspectors recommend these are installed.
  • Service panels with 6 main service disconnects are no longer permitted
  • Line side barrier requirements are required and expanded to service beyond the main electric panels. (This is for shock protection. The barriers protect from energized conductors on the line terminals of the main over current protection device in a service panel) – Picture above
  • Short Circuit Current Ratings connectors and devices must be marked suitable for use on the line side of the service equipment. We are seeing more of these devices as homeowners are looking for energy efficiency. – Picture above
  • Temporary power equipment (we see this on new construction that is not complete) require markings for available fault current and date of calculation. For temporary over current devices between 150 volts to ground and 1000 volts phase to phase will be current limiting
  • ARC reduction for services 1200 amps and greater must ensure arcing currents activate ARC reduction technology.

Monday, September 2, 2019

Receptacles in Areas That Are Damp or Wet


Receptacles in Areas That Are Damp or Wet


 

As home inspectors we always recommend Ground Fault Circuit Interrupters (GFCI) receptacles are installed in wet or damp areas. We should also be looking at the cover on the receptacle; there is a difference. There is also a difference, by definition of a “wet” or “damp” area. A wet area is defined as being exposed to large amounts of water (on an exterior wall not protected by a roof, near a pool or hot tub). A damp area is defined as being exposed to small amounts of liquid (basement, crawl space, under an awning). Receptacles located in wet areas should have a cover that is weatherproof when a plug is in it. Receptacles located in damp areas should have a cover that is weatherproof when a plug is not in it. They have a cap that covers the receptacle. As earlier stated they will be either GFCI or AFCI protected. So what should a home inspector be looking for:

·         Loose or damaged receptacles
·         Protective cover is damaged, loose or missing
·         Gap between receptacle and protective cover plate
·         Incorrect ampacity
·         Improperly wired
·         Unapproved exterior wiring used
·         Open ground / reversed polarity
·         Scorching
·         Serviced by an extension cord, drop cord, or other unapproved wiring methods
·         Unsafe location
·         240 Volt circuit not supplied by a 4 conductors